Abstract
Time-resolved admittance measurements provide the basis for studies showing that membrane fusion occurs through the formation and widening of an initially small pore, linking two previously separated aqueous compartments. Here we introduce modifications to this method that correct the cell-pipette (source) admittance for attenuation and phase shifts produced by electrophysiological equipment. Two new approaches for setting the right phase angle are discussed. The first uses the displacement of a patch-clamp amplifier C-slow potentiometer for the calculation of phase. This calculation is based on amplitudes of observed and expected (theoretical) changes in the source admittance. The second approach automates the original phase adjustment, the validity of which we prove analytically for certain conditions. The multiple sine wave approach is modified to allow the calculation of target cell membrane parameters and the conductance of the fusion pore. We also show how this technique can be extended for measurements of the resting potential of the first (voltage-clamped) membrane. We introduce an algorithm for calculation of fusion pore conductance despite a concurrent change in the resistance of the clamped membrane. The sensitivity of the capacitance restoration algorithm to phase shift errors is analyzed, and experimental data are used to demonstrate the results of this analysis. Finally, we show how the phase offset can be corrected "off-line" by restoring the shape of the capacitance increment.
Full Text
The Full Text of this article is available as a PDF (138.0 KB).
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Barnett D. W., Misler S. An optimized approach to membrane capacitance estimation using dual-frequency excitation. Biophys J. 1997 Apr;72(4):1641–1658. doi: 10.1016/S0006-3495(97)78810-6. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Breckenridge L. J., Almers W. Currents through the fusion pore that forms during exocytosis of a secretory vesicle. 1987 Aug 27-Sep 2Nature. 328(6133):814–817. doi: 10.1038/328814a0. [DOI] [PubMed] [Google Scholar]
- Curran M. J., Cohen F. S., Chandler D. E., Munson P. J., Zimmerberg J. Exocytotic fusion pores exhibit semi-stable states. J Membr Biol. 1993 Apr;133(1):61–75. doi: 10.1007/BF00231878. [DOI] [PubMed] [Google Scholar]
- Donnelly D. F. A novel method for rapid measurement of membrane resistance, capacitance, and access resistance. Biophys J. 1994 Mar;66(3 Pt 1):873–877. doi: 10.1016/s0006-3495(94)80863-x. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Joshi C., Fernandez J. M. Capacitance measurements. An analysis of the phase detector technique used to study exocytosis and endocytosis. Biophys J. 1988 Jun;53(6):885–892. doi: 10.1016/S0006-3495(88)83169-2. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Lanzrein M., Käsermann N., Weingart R., Kempf C. Early events of Semliki Forest virus-induced cell-cell fusion. Virology. 1993 Oct;196(2):541–547. doi: 10.1006/viro.1993.1509. [DOI] [PubMed] [Google Scholar]
- Lindau M., Neher E. Patch-clamp techniques for time-resolved capacitance measurements in single cells. Pflugers Arch. 1988 Feb;411(2):137–146. doi: 10.1007/BF00582306. [DOI] [PubMed] [Google Scholar]
- Lindau M. Time-resolved capacitance measurements: monitoring exocytosis in single cells. Q Rev Biophys. 1991 Feb;24(1):75–101. doi: 10.1017/s0033583500003279. [DOI] [PubMed] [Google Scholar]
- Lollike K., Borregaard N., Lindau M. The exocytotic fusion pore of small granules has a conductance similar to an ion channel. J Cell Biol. 1995 Apr;129(1):99–104. doi: 10.1083/jcb.129.1.99. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Neher E., Marty A. Discrete changes of cell membrane capacitance observed under conditions of enhanced secretion in bovine adrenal chromaffin cells. Proc Natl Acad Sci U S A. 1982 Nov;79(21):6712–6716. doi: 10.1073/pnas.79.21.6712. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Plonsky I., Zimmerberg J. The initial fusion pore induced by baculovirus GP64 is large and forms quickly. J Cell Biol. 1996 Dec;135(6 Pt 2):1831–1839. doi: 10.1083/jcb.135.6.1831. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Rohlicek V., Schmid A. Dual-frequency method for synchronous measurement of cell capacitance, membrane conductance and access resistance on single cells. Pflugers Arch. 1994 Aug;428(1):30–38. doi: 10.1007/BF00374749. [DOI] [PubMed] [Google Scholar]
- Spruce A. E., Iwata A., White J. M., Almers W. Patch clamp studies of single cell-fusion events mediated by a viral fusion protein. Nature. 1989 Nov 30;342(6249):555–558. doi: 10.1038/342555a0. [DOI] [PubMed] [Google Scholar]
- Zimmerberg J., Blumenthal R., Sarkar D. P., Curran M., Morris S. J. Restricted movement of lipid and aqueous dyes through pores formed by influenza hemagglutinin during cell fusion. J Cell Biol. 1994 Dec;127(6 Pt 2):1885–1894. doi: 10.1083/jcb.127.6.1885. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Zimmerberg J., Curran M., Cohen F. S., Brodwick M. Simultaneous electrical and optical measurements show that membrane fusion precedes secretory granule swelling during exocytosis of beige mouse mast cells. Proc Natl Acad Sci U S A. 1987 Mar;84(6):1585–1589. doi: 10.1073/pnas.84.6.1585. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Zimmerberg J. Simultaneous electrical and optical measurements of individual membrane fusion events during exocytosis. Methods Enzymol. 1993;221:99–112. doi: 10.1016/0076-6879(93)21010-6. [DOI] [PubMed] [Google Scholar]