Skip to main content
. 2008 Oct 29;28(44):11250–11262. doi: 10.1523/JNEUROSCI.2862-08.2008

Table 2.

Properties of the same place cells recorded in both the cylinder and chamber

Property Cylinder Chamber floor Chamber floor compared with cylinder
Firing rate (AP/s) 1.00 ± 0.07 0.96 ± 0.004 t(221) = 0.8; p > 0.4
In-field rate (AP/s) 2.1 ± 0.1 1.9 ± 0.08 t(479) = 2.1; p < 0.04
Out-of-field rate (AP/s) 0.09 ± 0.009 0.10 ± 0.008 t(221) = 1.0; p > 0.3
Information content (bits/AP) 2.0 ± 0.08 1.8 ± 0.07 t(221) = 1.8; p > 0.07
Coherence (std units) 0.63 ± 0.02 0.68 ± 0.01 t(221) = 2.2; p < 0.03
No. of place fields 1.3 ± 0.05 3.2 ± 0.18 t(221) = 10.6; p < 0.001
Place field size (pixels) 52.4 ± 3.5 94.6 ± 8.9 t(479) = 3.3; p < 0.001
Place field size (proportion of space) 0.24 ± 0.02 0.092 ± 0.009 t(479) = 9.5; p < 0.001
Proportion of active pixels 0.38 ± 0.02 0.35 ± 0.02 t(221) = 1.34; p > 0.17

Only the data from the cylinder recording before the chamber session are considered. Significant differences are highlighted in bold.