Table 3. Comparison of KS30, AT30, IS30, DS30 in all* PD patients versus controls.

Mean KS30 (95% CI) Median AT30 (IQR) Median IS30 (IQR) Median DS30 (IQR)
PD 44.2 (40.9, 47.5) 138.7 (100.5, 221.0) 13813 (8744, 29857) 1.042 (1.014, 1.147)
Controls 60.3 (57.6, 63.0) 97.3 (80.7, 131.2) 6758 (4030, 16664) 1.044 (1.013, 1.110)
p-value <0.0001 <0.0001 0.0003 0.45
KS30 Sensitivity AT30 Sensitivity IS30 Sensitivity
(cut-off) (cut-off) (cut-off)
Specificity 90% 44.8%* (42.5) 31.0%* (183) 24.1%* (29954) -
Specificity 85% 50.0% (46.0) 39.7% (156) 29.3% (23527) -
Specificity 80% 56.9% (48.3) 43.1% (149) 36.2% (18527) -

PD, Parkinson's disease; KS30, kinesia score; AT30, akinesia time; IS30, incoordination score; DS30, dysmetria score; CI, confidence interval; IQR, interquartile range.

*If analyses were limited to include only patients that were ‘Off’ (n = 20) the sensitivities (and cut-off) for 90% specificity for KS30, AT30 and IS30 were 65% (43), 50% (175) and 55% (29373) respectively.