Skip to main content
. 2005 Jun 16;128(1):156–161. doi: 10.1016/j.jviromet.2005.03.022

Table 2.

Concentration and detection of SARS-CoV from 2500-ml sewage in the 309th Hospital of PLAa

Date Patients in hospital Patientsb with symptoms f2 input f2 recovered (%) Cell culturec Concentrate + PCRd Inoculated cell + PCRe Residual chlorinea
11 June 7 0 1.3 × 106 93.1 f +g +
12 June 6 0 2.1 × 106 87.5 + +
13 June 3 0 1.3 × 106 96.9 + +
14 June 2 0 1.3 × 106 70.0 + +
15 June 2 0 3.0 × 105 62.2 + +
a

Glass column diameter: 19 mm, bed height: 14 cm, eluate volume: 500 ml.

b

With any one of the symptoms of fever, malaise, cough, dyspnea, except chest radiography signs.

c

Cell culture was maintained for 14 days to observe the cytopathic effect.

d

PCR template was from the concentrates.

e

Template from the cultured cells.

f

Negative.

g

Positive.